Ariston 110 L Manual técnico - Página 36

Procurar online ou descarregar pdf Manual técnico para Aquecedor de água Ariston 110 L. Ariston 110 L 39 páginas. Heat pump water heater split

Ariston 110 L Manual técnico
Component
heating element
zone and hot
Boiling
water sensors
water or
steam
-
from taps
mainboard
Component
Noise
increases
from the
fan
external
evaporator
unit
Component
Frequent
electrical
resistance
functioning
heating element
zone, air,
evaporator and
hot water sensors
fan
evaporator
Component
Bad odor
Component
Bad water
outlet water pipe
quality
For other problems please contact local technical assistance.
Fault cause
Fault mode
faulty component → out of tune
incorrect positioning
High level of scaling of the boiler and
components
faulty component → malfunctioning
Fault cause
Fault mode
Components vibration
physical impediments to the movement of
fan blades → malfunction
due to ice, leafs, dirt → partially clogged
Fault cause
Fault mode
"Time W" value too low
Air temperature out of range
Are not yet past 8 days from:
First Time installation
change of the parameter Time-W
No power from mains
P7 parameter set to OFF and outside
air temperature below 10 ° C
faulty component → out of tune
incorrect positioning
physical impediments to the movement of
fan blades → malfunction
due to ice, leafs, dirt → partially clogged
Fault cause
Fault mode
Absence of a siphon or siphon empty
Fault cause
Fault mode
dielectric connection missing → corrosion
What to check
Verify with a tester that the resistance
between terminals is compliant with
the "SENSOR TEST TABLE"
Verify the proper positioning
Drain the tank and check the
component
Check if the water heating doesn't stop
even if the set point temperature is
reached
What to check
Check the components fixed with
screws
Visual check of the component
Visual check of the component
What to check
Check P9 parameter on Installer menu
Verify the compliance of the
environmental conditions
Verify with a tester that the resistance
between terminals is compliant with
the "SENSOR TEST TABLE"
Verify the proper positioning
Visual check of the component
Visual check of the component
What to check
Check the presence of the siphon and
the level of water inside
What to check
Verify the presence of the connection
36
What to do
If the component is faulty, replace it
Place the component in the right
position
Provide water with proper hardness
degree
If the component is faulty, replace it
What to do
Be sure that the screws are tight
Clean the component
Clean the component
What to do
Increase the availability of heating
time
Wait 8 days and recheck
If the component is faulty, replace it
Place the component in the right
position
Clean the component
Clean the component
What to do
Provide a siphon with the right level
of water
What to do
Clean the pipe and provide a
dielectric connection