Ariston 80 L Manual técnico - Página 18
Procurar online ou descarregar pdf Manual técnico para Aquecedor de água Ariston 80 L. Ariston 80 L 39 páginas. Heat pump water heater split
PRO-TECH Anode + Magnesium anode
The exclusive PROfessional TECh system solution is an anodic anti-corrosion electronic protection system with a modulated
current (24 V).
It ensures maximum durability in terms of the boiler used in the water heater. The electronic circuit creates a difference in
potential between the boiler and the titanium electrode, so that optimal boiler protection is guaranteed, thereby preventing its
corrosion.
The magnesium anode is intended as a "start up" protection and is not necessary to replace it, in fact the permanent protection
is ensured by electrically connected PRO-TECH anode.
BEWARE! when the product is not supplied via power line, the product is not protected by the Pro-tech anode.
USE ONLY ORIGINAL SPARE PARTS.
HEAT PUMP START-UP PROCEDURE
Compressor safety times: the minimum time between an heat pump start up and the other is 5 minutes; the minimum "rest"
time (OFF time) is 4 minutes.
Heat pump start up procedure: how to check the correct components sound timings.
18