Aeotec TriSensor Manual do utilizador - Página 15

Procurar online ou descarregar pdf Manual do utilizador para Acessórios Aeotec TriSensor. Aeotec TriSensor 18 páginas.

Aeotec TriSensor Manual do utilizador
29-1-2019
4
Yelllow
5
Pink
6
Cyan
7
Purple
8
Orange
15. Wakeup report LED.
This setting changes the color of the LED when your TriSensor sends a wakeup report.
Parameter
Size Value Description
#
15
1
0
Disable [Default]
1
Red
2
Green
3
Blue
4
Yelllow
5
Pink
6
Cyan
7
Purple
8
Orange

Temperature controls.

20. Temperature Scale Setting.
You can control what scale is reported from your temperature sensor.
Parameter
Region Size Value Default
#
20
EU/AU 1
US
1
Value and Description;
0 = Celcius
1 = Fahrenheit
21. Temperature Threshold reporting.
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scales
with Parameter 64 change to C or F. Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on
Parameter 64) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F).
Parameter
Size Value Description
#
21
2
0
Disable Threshold Report for Temperature Sensor
Sets threshold for inducing automatic report using
1 -
a scale of
250
0.1 * value = temperature threshold
23. Temperature automatic report based on time.
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is
longer.
https://aeotec.freshdesk.com/support/solutions/articles/6000195459-trisensor-user-guide-
0 - 1 0
0 - 1 1
TriSensor user guide. : Aeotec
15/18