Ariston NUOS FS 200 Instruções de instalação e manutenção - Página 20

Procurar online ou descarregar pdf Instruções de instalação e manutenção para Aquecedor de água Ariston NUOS FS 200. Ariston NUOS FS 200 44 páginas. External air source heat pump water heater

Ariston NUOS FS 200 Instruções de instalação e manutenção
5.4 P
L
RODUCT
ABEL
MAX. TANK PRESSURE
TYPE/QUANTITY OF REFRIGERANT
POWER CONSUMPTION
HEAT PUMP HEAT RATING
POWER CONSUMPTION ELECTRIC
F
. 5.4
P
IG
A
RODUCT
5.5 R
EGULATIONS
5.6 W
R
ATER
EGULATIONS
5.7 B
R
UILDING
EGULATIONS
5.8 IEE W
R
IRING
B
S
RITISH
TANDARDS
20
MODEL
HEAT PUMP
HEATING ELEMEMENT
L
ABEL
The appliance should be installed in accordance with the Domestic Heating
Compliance Guide and BS 3456.
These regulations (bye-laws in Scotland), ensure a good supply of
wholesome water and that only approved materials, pipes and fittings are
used to convey water.
These are a statutory document and take priority over all other regulations
and recommendations. The installation of an unvented hot water storage
cylinder is classified as a 'Controlled Service' and Regulation G3 applies.
To meet the requirements of the Regulation, installation of an unvented
system should be undertaken by a 'competent installer'.
All installations of unvented hot water storage systems having a capacity
of more than 15 litres should be notified to the relevant Local Authority by
means of building notice or by the submission of full plans. It is important
to note that it is a criminal offence to install an unvented hot water storage
system without notifying the Local Authority. The installation of the unvented
cylinder and hot water system must comply with BS 6700 and the HSE
Legionella Code of Practice.
/
The appliance should be installed in accordance with the current versions
EGULATIONS
the IEE Wiring Regulations (now called BS7671 "Requirements for
electrical installations")
IPX4
IP RATING
CAPACITY
SERIAL NUMBER
VOLTAGE / FREQUENCY
MAXIMUM POWER CONSUMPTION
WEIGHT WHEN FULL
MAX PRESSURE HEAT PUMP
CIRCUIT HI/LOW PRESSRE SIDE
SYMBOLS
TANK PROTECTION