6)
Basic Set Value Settings for Group 2
'0' – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is
triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is
cleared.
'1'– Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is
triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is
cleared.
'2' – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is
triggered.
'3' – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is
triggered.
'4' – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is
cleared. '5' – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event
is cleared.
Parameter Number
6
7)
Temperature Alarm Value
This parameter is configured the threshold value that alarm level for temperature. When the
current ambient temperature value is larger than this configuration value, device will send a
BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than
this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3.
Value = [Value] × 0.1(Celsius / Fahrenheit)
Parameter Number
EU/AU
7
US
8)
Led Indicate Disable
This parameter is configured the Led light on disable or enable.
'1' – Enable Led Blink when device detects a motion event.
'0' – Disable Led Blink. This configuration is not affect inclusion, exclusion and reset.
Parameter Number
10
9)
Led Color For Motion Event Report
'0' – Disable.
'1' – Red.
'2' – Green.
'3' – Blue.
'4' – Yellow.
'5' – Pink.
'6' – Cyan.
'7' – Purple.
'8' – Orange.
Parameter Number
11
Size (Byte)
1
Size (Byte)
Available Settings
2
-400~850 (Celsius)
2
-400~1185 (Fahrenheit)
Size (Byte)
1
Size (Byte)
1
Available Settings
0 ~ 5
Available Settings
0, 1
Available Settings
0 ~ 8
Default value
0
Default value
239 (Celsius)
750 (Fahrenheit)
Default value
1
Default value
2