Ariston STD 150 DIRECT Manual do utilizador - Página 12

Procurar online ou descarregar pdf Manual do utilizador para Aquecedor de água Ariston STD 150 DIRECT. Ariston STD 150 DIRECT 16 páginas. Unvented cylinder range

Ariston STD 150 DIRECT Manual do utilizador
FIG. 8

RECOMMENDED ECONOMY 7 SYSTEMS

SYSTEM A
SYSTEM B
- 22 -
FIG. 9
a) SINGLE ELEMENT
RECOMMENDED ECONOMY 7 SYSTEMS
L1
N
THE IMMERSION HEATER SHALL BE INSTALLED WITH 85°C
RUBBER INSULATED HOFR-SHEATHED FLEXIBLE CORDS
COMPLYING WITH TABLE 8 OF BS 6141 : 1981
THE FOLLOWING DRAWING MUST BE REFERRED TO BEFORE
THE SIDE MOUNTED IMMERSION HEATER IS REPLACED.
WALL
- 23 -
THERMAL
THERMOSTAT
CUT-OUT
PIPES
THERMOSTAT POCKET
DIAG. 4
DAY
ELEMENT
3 KW
240 V