b.
Neutral wire connection: Connect the Neutral
wire to the "N" terminal on the Nano Switch.
c.
Load wire connection: Connect the Load wire
to the "OUT" on the Nano Switch.
d.
External/manual Switch connection: Connect
2 18AWG wires to the "S1" and "S2" on the
Nano Switch.
e.
External/manual Switch connection: Connect
2 18AWG wires form the 2 terminals on the
External/manual Switch to the Live wire.
b
a
c
d
N
L
IN
OUT S1 S2
e
12
LED will be on for 2 seconds and then return to a
colourful gradient.
Including Nano Switch as a secure device:
In order to take full advantage of the Nano Switch,
you will want your Nano Switch as a security device
that uses encrypted messages to communicate in
your Z-wave network. A security enabled controller/
gateway (or Z-Wave Plus controller) is required.
1.
Set your Z-Wave Plus controller into pairing
mode.
2.
Press the Action Button 2 times within 1 second
on the Nano Switch, the blue LED (secure
indication) will blink to indicate the Nano Switch is
entering into secure pairing mode.
3.
If the Nano Switch has been successfully added
to your Z-Wave network, its RGB LED will be
solid. If the pairing was unsuccessful, the red
LED will be on for 2 seconds and then remain a
colourful gradient, repeat the instructions above
from step 1.