Ariston Comfort STI 150 indirect Manual de instruções de instalação e utilização - Página 5
Procurar online ou descarregar pdf Manual de instruções de instalação e utilização para Caldeira Ariston Comfort STI 150 indirect. Ariston Comfort STI 150 indirect 24 páginas. Type c
Também para Ariston Comfort STI 150 indirect: Manual do utilizador (16 páginas), Manual de instruções de instalação (20 páginas)
www.tradeplumbing.co.uk Call Sales On 08708034288
2.4
O
D
VERALL
IMENSIONS
Model
DIRECT RANGE
Wall-hung
ST 50
ST 80
ST 100
Floor Standing
STD ProTech
STD / STD ProTech / ITD 125
STD / STD ProTech / ITD 150
STD / STD ProTech / ITD 210
STD / STD ProTech / ITD 300
500 STD ProTech
INDIRECT RANGE
STI / STI ProTech / ITI 125
STI / STI ProTech / ITI 150
STI / STI ProTech / ITI 210
STI / STI ProTech / ITI 300
500 STI ProTech
*ITD Models **ITI Models
2.5
C
W
S
OLD
ATER
2.6
S
F
ITING AND
IXING
www.tradeplumbing.co.uk Call Sales On 08708034288
Storage
Units Pipe Size
Capacity
Inlet Outlet
50 l
1/2"
75 l
3/4"
100 l
3/4"
100 l
3/4"
125 l
3/4"
150 l
3/4"
200 l
3/4"
300 l
3/4"
495 l
1"
125 l
3/4"
150 l
3/4"
200 l
3/4"
3/4"
300 l
1"
495 l
ST ProTech
STD/STD ProTech/ITD
50-80-100
125-150-200-300
It is important to ensure that the cold water main is capable of supplying the
UPPLY
increased demand which will be imposed on it. Hot and cold water are both
drawn off the same source of supply. Remember, there will not be a storage
tank to help compensate for variations in the demand on the system.
A minimum pressure of approximately 1.5 bar and 20 litres per minute is
required for satisfactory operation. 85% of UK dwellings have a mains
pressure above 2.0 bar.
N
OTE
The cylinder should be left packed until it is time to install. When unpacking
the appliance follow the guidelines within the packaging and take care not to
damage the temperature and pressure relief valve.
The cylinder may be installed at any convenient position, as it is connected
to the mains cold water supply, it is equally effective on any floor, however,
consideration must be given to allow ease of access for maintenance
purposes.
However, do not install the unit in premises which may be subject to
freezing. Ensure that the floor load bearing strength is adequate to take the
weight of the cylinder when full of water (see T
The ST50, ST80 and ST100 ProTech models are wall mounted. All other
models are free standing. These are supplied with feet which are attached to
the heater via self-tapping screws which are also supplied. All units must be
installed in the VERTICAL POSITION.
For maintenance purposes leave at least 500 mm free space in front of the
unit, for access.
Coil
Surface
m
2
A
B
-
410
120
-
590
175
-
550
175
-
530
650
-
700
805
-
840
965
-
990
1280
-
1215
1555
-
1390
335
0.75
700
805
0.9
840
965
0.9
990
1280
0.9
1215
1555
1.5
1390
335
STI/STI ProTech/ITI
125-150-200-300
: THE MAINS WATER SUPPLY MUST NOT EXCEED 16 BAR.
T
1
ABLE
Dimensions in mm
C
D
E
F
580
160
475
460
740
230
475
460
700
230
575
560
890
-
-
505
1045
-
-
505
1205
-
-
505
1525
-
-
505
1790
-
-
560
1870
-
-
714
1045
675
-
505
1205
815
-
505
1525
815
-
505
1790
815
-
560
1870
700
-
714
500 STD ProTech
500 STI ProTech
1).
ABLE
Weight
When Full
G
H
Kg
77
115
141
265
225
129
265
225
158/138*
265
225
190/164*
265
225
245/220*
275
255
385/331*
630
265
225
166/143**
265
225
201/171**
265
225
256/227**
275
255
395/337**
641
5