3Com HiPer DSP Manual de iniciação - Página 13
Procurar online ou descarregar pdf Manual de iniciação para Placa de rede 3Com HiPer DSP. 3Com HiPer DSP 17 páginas. Network application card
A
Trouble Clearing
Symptom
The RN/FL LED is solid red
The ALM LED is solid red
The Fault LED is solid red
T
ROUBLE
T
ECHNICAL
This table provides HiPer Digital Signal Processor (DSP) Network
Application Card (NAC) trouble clearing information for problems
occurring at power-up.
Cause
Critical failure.
The NAC has detected no span
connected to the NIC or the span
options are not configured
properly.
The diagnostics failed while the
card was booting.
C
LEARING AND
S
PECIFICATIONS
1 Remove NAC and reinstall.
2 If the boot problem persists after
1 Verify that your NIC is installed
2 Consult the HiPer DSP Product
1 Connect to the HiPer DSP NIC
2 Remove the NAC from the slot
3 Note the error codes reported on
4 Contact 3Com Technical Support
Trouble Clearing
the NAC goes through its boot-up
routine, contact 3Com Technical
Support.
correctly and that the span is
connected to the NIC properly.
Reference to verify that the span
lines are configured properly.
console port per the instructions
in the HiPer DSP T1/E1 NIC
Getting Started Guide.
and reinstall it using the
instructions in this guide.
the command line interface (CLI).
and give them the error codes to
assist in the trouble clearing
process.