Aeotec Nano Shutter Manual - Página 5

Procurar online ou descarregar pdf Manual para Controlador Aeotec Nano Shutter. Aeotec Nano Shutter 7 páginas. Z-wave motor controller

AU
230V 50Hz, Max: 2.5A
BR
220V 60Hz, Max: 2.5A
CN
220V 50Hz, Max: 2.5A
EU
230V 50Hz, Max: 2.5A
IN
230V 50Hz, Max: 2.5A
UK
230V 50Hz, Max: 2.5A
US
120V 60Hz, Max: 2.5A

Association information

Nano Shutter supports 2 association groups and Max 5 nodes for every group.
Association
Nodes Send
Group
Group 1
[1,5]
Group 2
[1,5]
Configuration parameters information
Parameter
Number
Hex / Decimal
0x23 (35)
0x50 (80)
Send commands
Mode
Single
When the state of Nano Shutter (turn on/off the load ) is
Cast
changed:
1. Set Configuration parameter 80 to 0: Send nothing (default).
2. Set Configuration parameter 80 to 1: Send the Basic Report.
Single
Forward the Basic Set, Binary set, Scene Activation Set to
Cast
associated nodes in Group 2 when the Nano Shutter receives
the Basic Set, Binary set, Scene Activation Set commands
from main controller.
(E.g. Send/forward Basic Set to control the other nodes in
association Group 2)
Description
Set the moving time from up (left) to down (right) for
curtain.
To set which report would be sent to the associated
nodes in association group 1 when the state of output
load is changed.
0 = Nothing
1 = Basic Report CC
Note:
When just only one channel load state is
changed, the report message Basic Report CC would
be Multi Channel encapsulated.
921.42MHz
921.42MHz
868.42 MHz
868.42 MHz
865.22 M Hz
868.42 MHz
908.42 MHz
Page 5
Default
Size
Value
30
1
0
1