The "A" Summer/Winter/Flue Test selector knob can be
set to <
> to bypass temperature adjustment on the
heating circuit for the purpose of analysing the fumes
produced by combustion. To access this mode, open a
water tap so that the flow rate is no less than 8 litres per
minute. Then push the "A" selector knob in and turn it
from <
> or <
> to the <
276
T
F
EST
EATURE
)
A
> position.
C
!
AUTION
The flue test function makes the boiler run continuously at its maximum power.
This condition should be used exclusively by authorised personnel.
The P.C.B. allows for the boiler to be pushed at its maximum or minimum thermal
capacity. For the relevant information, refer to section 3.7.5. of the "I
I
".
NSTRUCTIONS
N.B. Should the boiler not be used for a long period of time, the condensate
trap must be filled up again before re-starting the boiler. Failure to add
water to the trap is dangerous because exhaust fumes could be released
into the environment.
T
M
EST
ODE
NSTALLATION
-26-