Switching off the boiler
To switch off the boiler press the ON/OFF button
will switch off.
The Anti-frost Function is allready active.
ATTENTION!!
Switch off the boiler completely by switching the exter-
nal electrical switch to the OFF position. Shut off the gas
valve.
18
/
, the display
HS C
Appliance shut-off conditions
The boiler is protected from malfunctions by means of internal
checks performed by the electronic P.C.B., which stops the boiler
from operating if necessary. In the event of the boiler being shut
off in this manner, a code appears on the control panel display
which refers to the type of shut-off and the reason behind it.
Two types of shut-off may occur:
Safety shut-off
This type of error is "volatile", which means that the boiler starts
up again automatically as soon as the
problem which caused the shut-off is
removed; Err" and the error code (e.g.
Err/110) ) flash on the display and the
symbol appears.
In fact, soon as the cause of the shut-off
disappears, the boiler starts up again
and continues to operate normally.
If the boiler still indicates a safety shut-off, switch it off. Make
sure the external electric switch is in the OFF position, shut off
the gas valve and contact a qualified technician.
Safety shut-off due to insufficient
water pressure
If the water pressure inside the
heating circuit is insufficient, the
boiler will perform a safety shut-off.
Code 108 (e.g. Err/108) will appear
on the display, in addition to the
symbol. The system may be
restarted, re-balancing the value, by using the filling procedure
- see note 1.
If the re-balancing request is performed on a frequent basis,
switch the boiler off, bring the external electric switch to the OFF
position, shut off the gas valve and contact a qualified technician
to check for any leaks of water.
NOTE 1 - FILLING PROCEDURE
TO RESTORE THE CORRECT PRESSURE OPEN
THE FILLING VALVE (POSITIONED IN THE BOTTOM
OF THE BOILER) AND PRESS THE MODE BUTTON
FOR 5 SECONDS. THE DISPLAY SHOWS "P".
WHEN THE PRESSURE GAUGE INDICATES A
PRESSURE BETWEEN 0.6 AND 1.5 BAR, CLOSE THE
FILLING VALVE AND PRESS THE MODE BUTTON.
THE DISPLAY RETURNS TO NORMAL VIEW.