Ariston micro SYSTEM 10 RFFI Manual de instruções de instalação - Página 20

Procurar online ou descarregar pdf Manual de instruções de instalação para Caldeira Ariston micro SYSTEM 10 RFFI. Ariston micro SYSTEM 10 RFFI 44 páginas. Type c boilers
Também para Ariston micro SYSTEM 10 RFFI: Manual do utilizador (16 páginas)

Ariston micro SYSTEM 10 RFFI Manual de instruções de instalação
6.

TECHNICAL INFORMATION

CE Certification
Heat Input
Heat Output
Efficiency of Nominal Heat Input
Efficiency at 30% of Nominal Heat Input
Heat Loss to the Casing (∆T=50°C)
Flue Heat Loss with Burner Operating
Flue Heat Loss with Burner Off
Maximum Discharge of Fumes (G20)
Residual Discharge Head
Consumption at Nominal Capacity(G20)
Gas Consumption after 10 Minutes*
(15°C, 1013 mbar) (G30-G31)
Temp. of exhaust fumes at nominal capacity °C
CO
Content
2
O
Content
2
CO Content
Minimum Ambient Temperature
Head Loss on Water Side (max) (∆T=20°C) mbar
Residual Head of System
Heating Temperature
Expansion Vessel Capacity
Expansion Vessel Pre-load Pressure
Maximum Water Content of System
Maximum Heating Pressure
Nominal Pressure
Electrical Supply
Power Consumption
Protection Grade of Electrical System
Internal Fuse Rating
Weight
G.C. Number
*Calculated at 70% maximum output
Manufacturer:
Commercial subsidiary: MTS (GB) LIMITED
Natural Gas (G20) mbar
LPG (G30-G31)
Merloni TermoSanitari SpA - Italy
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600
Fax: (01494) 459775
Internet: http://www.mtsgb.ltd.uk
Technical Service Hot Line: (01494) 539579
0063BL4994
max kW
max kW
%
%
%
%
%
Kg/h
mbar
m
3
/h
m
3
Kg/h
%
%
ppm
°C
bar
max/min °C
l
bar
l
bar
mbar
V/Hz
W
IP
FAST 2 AT
Kg
10 RFFI
11.6
10.5
81.3
79.2
3.2
6.1
0.2
23.7
0.3
1.22
0.13
0.91/0.90
121.7
6.94
8
31.5
+5
200
0.25
82/42
6
1
130
3
20
30-37
230/50
105
X4D
30
41-116-04