Ariston microSYSTEM 28 RFFI Manual de instruções de instalação - Página 11
Procurar online ou descarregar pdf Manual de instruções de instalação para Caldeira Ariston microSYSTEM 28 RFFI. Ariston microSYSTEM 28 RFFI 48 páginas. Microsystem
Também para Ariston microSYSTEM 28 RFFI: Manual do utilizador (16 páginas), Manual de instruções de instalação (24 páginas)
Exhaust
Type
21 RFFI
C12 (xx)
Coaxial
Systems
C32 (xx)
C42 (xx)
ø 60/100
Exhaust
Type
28 RFFI
Coaxial
C12 (xx)
Systems
C32 (xx)
ø 60/100
C42 (xx)
Exhaust
Type
21 RFFI
C12 (xy)
C32 (xy)
Twin Pipe
C42 (xy)
Systems
ø 80/80
C52 (xy)
C82 (xy)
Exhaust
Type
28 RFFI
C12 (xy)
C32 (xy)
Twin Pipe
C42 (xy)
Systems
ø 80/80
C52 (xy)
C82 (xy)
T
P
WIN
IPE
S
YSTEMS
F
. 2.10
IG
Restrictor
Maximum
Extension
ø 46 mm
Exhaust/Air
L min = 0.5 m
L = 4 m
L max = 1 m
Restrictor
Maximum
Extension
ø 41 mm
Exhaust/Air
L min = 0.5 m
L = 4 m
L max = 1 m
Restrictor
Maximum
ø 46 mm
Extension
Exhaust/Air
34 m
L max = 25 m
34 m
34 m
L max = 22 m
31 m
Restrictor
Maximum
ø 41 mm
Extension
Exhaust/Air
62 m
L max = 38 m
62 m
62 m
L max = 34 m
54 m
Risk of Condensation Forming
Piping not insulated
ø 46
restrictor
NO restrictor
NONE
NONE
Risk of Condensation Forming
Piping not insulated
ø 41
restrictor
NO restrictor
NONE
NONE
Risk of Condensation Forming
Piping not insulated
ø 46
NO
restrictor
restrictor
3.0 m
4.5 m
3.3 m
4.8 m
Risk of Condensation Forming
Piping not insulated
ø 41
NO
restrictor
restrictor
8 m
11 m
8 m
11 m
11
Piping insulated
ø 46
restrictor
NO restrictor
NONE
NONE
Piping insulated
ø 41
restrictor
NO restrictor
NONE
NONE
Piping insulated
ø 46
NO
restrictor
restrictor
12.5 m
16.0 m
14.0 m
17.8 m
Piping insulated
ø 41
NO
restrictor
restrictor
19 m
31 m
19 m
31 m
In calculating the lengths of the pipes, the
maximum length "L" must also take into
consideration
the
exhaust/air intake end terminals, as well
as 90° elbows for coaxial systems.
The C52 types must comply with the
following requirements:
1 - The exhaust/ air intake pipes must
have the same diameter of
2 - If elbows are to be inserted into the
air intake and/or exhaust system, the
calculation of the overall length must
take into consideration the values for
each elbow, see the F
A
M
CCESSORIES
ANUAL
3 - The exhaust pipe must protrude by at
least 0.5 m above the top of the roof
in the event that it is located on the
opposite side of the building to the
side with the air intake (this condition
is not obligatory when the air intake
and exhaust are located on the same
side of the building).
T
2.1
ABLE
values
for
the
80 mm.
ø
P
L U E
I P E
.