Installation

GB
! Please keep this instruction booklet in a safe place for future reference. If
the appliance is sold, given away or moved, please make sure the booklet is
also passed on to the new owners so that they may benefit from the advice
contained within it.
! Please read this instruction manual carefully: it contains important information
concerning the safe operation, installation and maintenance of the appliance.
Positioning
! Do not let children play with the packaging material; it should be disposed
of in accordance with local separated waste collection standards (see
Precautions and tips).
! The appliance must be installed by a qualified professional in accordance
with the instructions provided. Incorrect installation may damage property or
cause harm to people or animals.
• The room must be equipped with an air extraction system that expels
any combustion fumes. This may consist of a hood or an electric fan that
automatically starts each time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as air is needed for
combustion to occur normally. The flow of air must not be less than 2 m
per kW of installed power.
A
Examples of
ventilation holes
for comburant air.
Adjacent
Room to be
Room
Vented
Enlarging the ventilation slot
between window and floor.
• Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore,
rooms containing LPG cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored in rooms or
storage areas that are below ground level (cellars, etc.). It is advisable to
keep only the cylinder being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens, fireplaces, stoves,
etc. ) which could raise the temperature of the cylinder above 50°C.
8
Directly to
the Outside
The air circulation system may take air directly
from the outside by means of a pipe with an
inner cross section of at least 100 cm
opening must not be vulnerable to any type
of blockages.
The system can also provide the air needed
for combustion indirectly, i.e. from adjacent
rooms fitted with air circulation tubes as
described above. However, these rooms must
not be communal rooms, bedrooms or rooms
that may present a fire hazard.
Built-in appliances
Use an appropriate cabinet to ensure that the appliance operates properly:
• The panels adjacent to the oven must be made of heat-resistant material.
• Cabinets with a veneer exterior must be assembled with glues which can
withstand temperatures of up to 100°C.
• To install the oven under the counter (see diagram) or in a kitchen unit,
the cabinet must have the following dimensions:
! The appliance must not come into contact with electrical parts once it has
been installed. The indications for consumption given on the data plate have
been calculated for this type of installation.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet must be
removed. It is advisable to install the oven so that it rests on two strips of
wood, or on a completely flat surface with an opening of at least 45 x 560
mm (see diagrams).
/h
3
; the
2
Centring and fixing
Secure the appliance to the cabinet by opening the oven door and inserting
4 screws into the 4 holes on the outer frame.
! All parts which ensure the safe operation of the appliance must not be
removable without the aid of a tool.