Electrical Connection

AUS
The electrical connection to the mains must be made on
the appliance. The power voltage and frequency are as
indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Fitting the power supply cable
L
N
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate (see side).
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum contact
opening of 3 mm installed between the appliance and the
mains, suitable for the load indicated and complying with
current electrical regulations (the earthing wire must not be
interrupted by the circuit-breaker). The supply cable must
not come into contact with surfaces with temperatures
higher than 50°C.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant with
safety regulations.
Before connecting to the power supply, make sure that:
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate (see
below).
• The voltage must be in the range between the values
indicated on the data plate (see below).
• The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
6
1. Open the terminal board
by inserting a screwdriver
into the side tabs of the
cover. Use the screwdriver
as a lever by pushing it
down to open the cover (see
diagram)
.
2. Install the power supply
cable by loosening the
cable clamp screw and the
three wire contact screws
L-N-
.
Connect the wires to the
corresponding terminals:
the Blue wire to the terminal
marked (N), the Brown wire
to the terminal marked (L)
and the Yellow/Green wire
to the terminal marked
(see diagram).
! Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
! The manufacturer declines any liability should these safety
measures not be observed.
APPLIANCE SPECIFICATIONS
width 43.5 cm
Dimensions*
height 32,4 cm
depth 41.5 cm
Volume*
59 l
width 45.5 cm
Dimensions**
height 32,4 cm
depth 41.5 cm
Volume**
62 l
voltage: 220 - 240 V~ 50/60 Hz
Electrical
(see data plate)
connections
maximum power absorbed
2800 W
Directive 2002/40/EC on the label
of electric ovens. Standard EN 50304
ENERGY
Declared energy consumption
LAB EL
for Forced convection Class –
heating mode:
ECO.
* Only for models with drawn rails.