Firenzo BRONTE TOP OUTLET RU Manual - Página 5

Procurar online ou descarregar pdf Manual para Fogão a lenha Firenzo BRONTE TOP OUTLET RU. Firenzo BRONTE TOP OUTLET RU 12 páginas. Freestanding woodburner
Também para Firenzo BRONTE TOP OUTLET RU: Manual (15 páginas)

Firenzo BRONTE TOP OUTLET RU Manual
3. FLOOR PROTECTOR
The heater should always be installed on top of its base due to high temperatures
sustained over long periods. The base must be anchored to both the floor protector
and the floor for seismic restraint. Anchor points are provided in the base or on the
rear legs.

PEDESTAL MODELS

insulated
An
floor protector is required consisting of a minimum thickness of
40mm of an approved insulation material i.e. 2 sheets 10mm micorboard or
superlux, 10mm tile backing board and 10mm tiles or similar on the top surface.
All joints on the upper surface should be sealed to prevent spilt ash from contacting
any heat sensitive material.
LEG BASE MODEL
Either an insulated floor protector OR a floor protector consisting of an upper surface,
including grouting, of a durable, non-combustible material.
FLOOR PROTECTOR DIMENSIONS
Refer to drawings under 4. Installation Clearances.
For the Bronte on a pedestal base the standard front clearance from the front of the
door glass can be reduced by increasing the floor protector height:
Floor Protector Height
Measurement from Door Glass 470 450

4. INSTALLATION CLEARANCES

When installing the Bronte RU Rear-Outlet on a leg base ADD 70mm to vertical
measurements shown:
Bronte Rear Outlet RU
REQUIREMENTS
:
:
40
50
60
420
3
:
70
80
90
400
375
350
100
110
330
300