Whirlpool  LER3622PQ Manual de utilização e cuidados - Página 8

Procurar online ou descarregar pdf Manual de utilização e cuidados para Secador Whirlpool  LER3622PQ. Whirlpool  LER3622PQ 20 páginas. Cabrioâ® high efficiency electric dryer with accudryâ„¢ drying system ventilation specification
Também para Whirlpool  LER3622PQ: Dimensões (1 páginas), Manual de utilização e cuidados (20 páginas), Manual de instruções (8 páginas)

Whirlpool  LER3622PQ Manual de utilização e cuidados
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center
terminal block screw. Tighten screw.
A
E
D
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center terminal block screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
A
F
E
D
A. External ground conductor screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
F. Ground wire (green or bare) of power supply cord
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connections. Now go to
"Venting Requirements."
8
C
B
C
B
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 1½" (38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1. Remove center terminal block screw.
2. Remove neutral ground wire from external ground
conductor screw. Connect neutral ground wire and
place the hooked end (hook facing right) of the neutral
wire (white or center wire) of direct wire cable under the
center screw of the terminal block. Squeeze hooked ends
together. Tighten screw.
A
E
D
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center terminal block screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
B
C