In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) ft. (1.8 m)
of the dryer.
The shut-off valve location should be easy to reach for opening
and closing.
C
A
B
A. 3/8" flexible gas connector
B. 3/8" NPT adapter
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be
connected to the gas supply. Listed here are some guidelines for
two different methods of connection.
This dryer must be connected to the gas supply line with
a listed flexible gas connector that complies with the standard for
connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Option 1 (Recommended Method):
Flexible stainless steel gas connector:
■ If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter
fitting between the stainless steel gas connector and the dryer
gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method):
Approved aluminum or copper tubing:
■ Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit).
■ If you are using Natural Gas, do not use copper tubing.
■ 3/8" flare x 3/8" NPT adapter fitting between dryer pipe and
3/8" approved tubing.
■ Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
■ If your dryer has been converted to use propane gas,
3/8" propane compatible copper tubing can be used. If the
total length of the supply line is more than 20 ft. (6.1 m), use
larger pipe.
NOTE: Pipe joint compounds that resist the action of propane
gas must be used. Do not use TEFLON
†TEFLON is a registered trademark of Chemours.
Dryer gas pipe
■ The gas pipe that comes out through the rear of your dryer
29" Wide Model
E
D
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
■ The design of this dryer is certified by CSA International for
Elevations up to 10,000 ft. (3,048 m):
■ When installed above 10,000 ft. (3,048 m), a 4% reduction of
Gas supply pressure testing
■ The dryer must be disconnected from the gas supply piping
tape.
†
has a 3/8" male pipe thread.
A
A. 3/8" NPT dryer pipe
A. 3/8" NPT dryer pipe
use at altitudes up to 10,000 ft. (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
A
A. 3/8" NPT dryer pipe
the burner B.T.U. rating shown on the model/serial number
plate is required for each 1,000 ft. (305 m) increase in
elevation.
system during pressure testing at pressures greater than
1/2 psi.
1¼"
(32 mm)
9¼"
(235 mm)
1¼"
(32 mm)
9¼"
(235 mm)
37