ELECTRIC DRYER POWER HOOKUP-
CANADA ONLY
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and
in conformance with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes standard
may be obtained from: Canadian Standards Association, 178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure wall
receptacle is within reach of dryer's final location.
For further information, please reference the service numbers
located in the "Assistance or Service" section.
GROUNDING
iNSTRUCTiONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction
or
breakdown,
grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an
equipment-grounding
conductor and a grounding
plug. The
plug must be plugged into an appropriate
outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING:
Improper connection of the
equipment-grounding
conductor can result in a risk of
electric shock. Check with a qualified electrician or service
representative or personnel if you are in doubt as to
whether the dryer is properly grounded. Do not modify the
plug provided with the dryer: if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
4-wire receptacle 14-30R
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.