Whirlpool WGD8800YC Manual de instalação - Página 12

Procurar online ou descarregar pdf Manual de instalação para Secador Whirlpool WGD8800YC. Whirlpool WGD8800YC 36 páginas. Gas dryer/canadian electric dryer
Também para Whirlpool WGD8800YC: Manual de instruções (8 páginas), Manual de utilização e cuidados (36 páginas)

Whirlpool WGD8800YC Manual de instalação

INSTALL vENT SYSTEM

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.

MAKE GAS CONNECTION

1.
connect gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
tape.
®†
12
12" min.
(305 mm)
12" min.
(305 mm)
Non-flared
male fitting
B
2.
Plan pipe fitting connection
D
C
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.

CONNECT INLET HOSES

For non-steam models, skip to "Connect Vent" on page 14.
The dryer must be connected to the cold water faucet using
the new inlet hoses. Do not use old hoses.
1.
Turn cold water off, remove and
replace rubber washer
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the "Y" connector.
Remove old rubber washer from inlet hose and replace with
new rubber washer provided.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
B
Open valve
A
B