Whirlpool WGD9500TC2 Manual de instruções de instalação - Página 12

Procurar online ou descarregar pdf Manual de instruções de instalação para Secador Whirlpool WGD9500TC2. Whirlpool WGD9500TC2 32 páginas. Gas (u.s.a. and canada) and electric (canada only) dryers

Whirlpool WGD9500TC2 Manual de instruções de instalação
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side or
through the bottom. If you prefer, you may contact your local dealer
to have the dryer converted.
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
A
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
A
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the "Assistance or Service"
section to order.
Over-the-Top Installation:
Part Number 4396028
12
B
C
B
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct
path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best
drying performance
Use the following vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the
Vent system chart.
Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The vent system chart provides venting requirements that will help
to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn inside
the dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Number
Type of vent
90º elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Box /louvered
Angled
hoods
hoods
64 ft (20 m)
58 ft (17.7 m)
54 ft (16.5 m)
48 ft (14.6 m)
44 ft (13.4 m)
38 ft (11.6 m)
35 ft (10.7 m)
29 ft (8.8 m)
27 ft (8.2 m)
21 ft (6.4 m)