Optional 3-wire Connection
You must verify with a qualified electrician that this grounding
method is acceptable before connecting.
1.
Prepare to connect neutral
ground wire and neutral wire
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire
and neutral wire
C
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
B
Connect remaining wires to outer terminal block screws
Tighten screws.
A
4.
Connect external ground wire
G
E
B
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements."
A