Whirlpool YWED85HEFW2 Manual de instruções de instalação - Página 10

Procurar online ou descarregar pdf Manual de instruções de instalação para Secador Whirlpool YWED85HEFW2. Whirlpool YWED85HEFW2 48 páginas.

MAKE GAS CONNECTION

(gas models only)
1.
Connect gas supply to dryer
A. Flared male tting
B. Non- ared male tting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non- ared male ttings. If exible metal
tubing is used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-
joint compound resistant to action of propane gas. Do not
use TEFLON
tape.
®
2.
Plan pipe tting connection (option 1)
A. 3/8" exible gas connector
B. 3/8" dryer gas pipe
A combination of pipe ttings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3.
Open shut-off valve
A
A. Closed valve
B. Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
10
B
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to- are adapter
tting
B

VENTING

Venting Requirements

WARNING:
To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used
for exhausting.
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent:
(Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced air ow and poor performance.
Do not install in enclosed walls, ceilings, or oors.
The total length should not exceed 7¾ ft. (2.4 m).
The length of exible metal vent used must be included
in the overall vent system design as shown in the Vent
System Charts.
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal
or exible metal vents. Review Vent System Charts and, if
necessary, modify existing vent system to achieve best drying
performance.
4"
(102 mm)