Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP Manual de instruções de instalação - Página 8
Procurar online ou descarregar pdf Manual de instruções de instalação para Campânula de ventilação Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP. Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP 16 páginas. 36" (91.4 cm) island-mount canopy range hood
Também para Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP: Instruções de instalação e manual de utilização e cuidados (28 páginas), Manual de utilização e cuidados (32 páginas)
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Install all burner caps and burner bases.
B
A. Burner cap
B. Igniter electrode
C. Burner base
D. Gas tube opening
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
The power cord on this appliance is equipped with a 3 prong grounding plug that mates with standard 3 prong grounding-type plug.
Verify proper operation after servicing.
8
B
A
D
C
WIRING DIAGRAM
Power Supply
N
G
L1
N
L1
18 W # 2
18 W # 9
20 OR # 19
20 OR # 20
# 1
# 5
Igniter
Igniter
20 OR # 23
# 3
Igniter
# 2
# 4
Igniter
Igniter
18 BU # 18
Valve
Valve
B
B
Switch
Switch
# 1
# 2
LR
A
A
LF
18 BK # 8
18 BK # 7
Wiring Diagram 36" (91.4 cm) Cooktop
Complete Installation
Electronic Ignition System
Check Operation of Surface Burners
1. Push in and turn the surface burner control knobs to the "HI"
position.
The surface burner flame should light within 4 seconds. The
first time a surface burner is lit, it may take longer that
4 seconds to light because of air in the gas line.
2. Check the flame on "HI" for a blue color. It should be clean
and soft in character. No yellow tip, blowing or lifting of flame
should occur. Occasional orange flashes are normal and
reflect different elements in the air or gas.
3. Repeat at "LO" position.
4. After verifying the proper burner operation, turn the control
knobs to "OFF."
If burners do not light properly:
Turn surface burner control knob to the "OFF" position.
Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
Check that the gas shutoff valves are set to the "open"
position.
Check that burner heads and caps are properly positioned on
burner bases.
Recheck operation of surface burners. If a burner does not light
at this point, contact your dealer or authorized service company
for assistance.
18 BK # 4
N
18 BU # 18
#1
L1
18 W # 13
N
18 BU # 17
#2
L1
18 W # 12
N
18 BU # 16
#3
L1
18 W # 11
N
18 BU # 15
#4
L1
20 OR # 22
18 W # 10
18 W # 9
N
#5
L1
20 OR # 21
Spark Module
18 BU # 17
18 BU # 16
18 BU # 15
Valve
Valve
Valve
B
B
B
Switch
Switch
Switch
# 3
# 4
# 5
CENTER
RF
RR
A
A
A
18 BK # 6
18 BK # 5
18 BK # 4