4. Remove the metal grease filters from the face panel. See the
"Range Hood Care" section.
5. Attach the face panel to the hood liner. (3 sizes: The 30" x 12"
[76.2 cm x 30.5 cm] cabinet size is shown.)
See instruction below for your specific cabinet size.
D
A
A. Screws - 3.5 x 9.5 mm flat-head (4)
B. Face plate (30" x 12" [76.2 cm x 30.5 cm] shown)
C. Cabinet (30" x 12" [76.2 cm x 30.5 cm] shown)
D. Screws - 4.2 x 15 mm truss-head (2)
For cabinet size - 30" x 12" (76.2 cm x 30.5 cm)
Attach the 30" x 12" (76.2 cm x 30.5 cm) face panel (supplied
with range hood) to the hood liner using four 3.5 x 9.5 mm
flat-head screws and two 4.2 x 15 mm truss head screws.
Tighten to secure.
For cabinet size - 30" x 18" (76.2 cm x 45.7 cm)
Assemble the 30" x 6" (76.2 cm x 15.2 cm) face panel rear
extension (see the "Assistance or Service" section to order)
to the 30" x 12" (76.2 cm x 30.5 cm) face panel (supplied with
the range hood) using eight 4.2 x 8 mm screws (supplied with
the face panel rear extension).
A
B
A. Screws - 4.2 x 8 mm (8)
B. Face panel
C. Face panel rear extension
Attach the 30" x 18" (76.2 cm x 45.7 cm) face panel
assembly to the hood liner using four 3.5 x 9.5 mm flat-head
screws and two 4.2 x 15 mm truss head screws. Tighten to
secure.
For cabinet size - 36" x 18" (91.4 cm x 45.7 cm)
Attach the 36" x 18" (91.4 cm x 45.7 cm) face panel (see the
"Assistance or Service" section to order) to the hood liner
using four 3.5 x 9.5 mm flat-head screws and two 4.2 x
15 mm truss head screws. Tighten to secure.
Connect the lamp electrical connector.
C
B
A
C
Connect the Vent System
Vented Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
Non-Vented (recirculating) Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
2. Install charcoal filters. See the "Range Hood Care" section.
To order replacement kits, see the "Assistance or Service"
section.
Complete Installation
1. Replace grease filters. See the "Range Hood Care" section.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
2. Plug 3-prong power cord into a grounded 3-prong outlet
located inside the cabinet above the range hood.
3. Check the operation of the range hood fan and light. See
"Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
11