Whirlpool UXL6036Y Dimensões do produto

Procurar online ou descarregar pdf Dimensões do produto para Campânula de ventilação Whirlpool UXL6036Y. Whirlpool UXL6036Y 1 páginas. Whirlpool 36" and 48"hood liner

Whirlpool UXL6036Y Dimensões do produto
36" and 48" Hood Liner
PRODUCT MODEL NUMBERS
UXL6036Y
UXL6048Y
Electrical Requirements: A 120-volt, 60-Hz, AC-only,
15-amp, fused electrical circuit is required.
CABINET DIMENSIONS
36" (91.4 cm) for 36" models
48" (121.9 cm) for 48" models
Hood support must be
capable of supporting
75 lb (34 kg)
IMPORTANT:
Minimum distance "X": 24" (61 cm) from electric
cooking surfaces.
Minimum distance "X": 30" (76.2 cm) from gas
cooking surfaces.
Suggested maximum distance "X": 36" (91.4 cm).
VENTING REQUIREMENTS
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
OVERALL DIMENSIONS
(31.4 cm)
" (12.2 cm)
"
(29.2 cm)
"
(12.8 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
22" (55.9 cm)
Hood liner depth
"X" bottom
of canopy to
cooking surface
12 "
" (70.1 cm)
" (75.8 cm)
" (91.4 cm) for 36" models
" (121.9 cm) for 48" models
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight vent
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent
feet (meters) for each vent piece used in the system.
Vent Piece
45° elbow
90° elbow
The maximum equivalent vent lengths are:
10" (25.4 cm) round vents - 60 ft (18.3 m)
Example vent system
90 elbow
2 ft
(0.6 m)
The following example falls within the maximum recommended vent
length.
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of system
" (45.7 cm) for 36" models
" (61.0 cm) for 48" models
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Equivalent Length
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
11" (27.9 cm)
10 " (25.7 cm)
22" (55.9 cm)
Ref. W10331011A
12/20/10