Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical shock.
8. Connect the green (or yellow/green)
ground wire to the
green/yellow
ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical
Connection
Inside Hood Liner Between
In-line
Blower System and Hood Liner
1. With the hood liner mounted (see the "Install Hood Liner"
section), locate the wiring cable connector
inside the hood
liner.
2. Connect the 6-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the hood liner.
3. Locate the terminal box inside the hood liner and install a
1/2"(1.3 cm) UL listed or CSA approved strain relief (see
"Complete
Preparation"
in the "Prepare Location" section).
4. Run the wire ends from the 6-wire connector assembly
through the 1/2"(1.3 cm) strain relief, leaving enough wire
length to make the wiring connections.
Tighten the strain
relief screws.
5. Connect the wires from the 6-wire connector assembly to the
wires from the wiring conduit inside the hood liner terminal
box.
6. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow)
ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors
(see the
"Make Electrical Power Supply Connection
to Hood Liner"
section).
B
C
A
D
7.
A. UL listed or CSA approved
½" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. 6-wire connector assembly
Go to the "Make Electrical Power Supply Connection to Hood
Liner" section.
vc <e
sec
cu Hc} p/e
y Colq/sec
Hood Shed
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Locate terminal box inside of the hood liner.
/
A
B
A. Terminal box cover
B. Terminal box
12