4.
Use saber or keyhole saw to cut the circular vent opening.
.5 H
i[
*From wail not
cabinet frame
_! 7V4" (18.4 cm) diam.
cabinet
cutouts
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements"
section.
2. Use caulking to seal exterior wall or roof opening around the
cap.
1.
2.
3.
Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
A. Keyhole
slot
Use V8" (3 mm) drill bit and drill 4 pilot holes as shown.
A
A. Drillpilot hole
Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
holes. Leave about 1/4"(6.4 cm) space between screw heads
and cabinet to slide range hood into place.
\.\\\\\'\\\\
=_
@-
1/4""
(6.4 ram)
4. Remove top rectangular and round vent knockouts.
A. Round vent knockout
B. Top rectangular
vent knockout
5. Remove metal grease filters. See the "Range Hood Care"
section.
NOTE: Your model will have a 7" (17.8 cm) round vent mounting
plate on the inside of your range hood.
6. Remove the 7" (17.8 cm) round vent mounting plate attached
with screws on the inside of your range hood.
7.
A. 7" (17.8 cm) round vent mounting plate
B. Screws
Install 7" (17.8 cm) round vent mounting plate. Attach to
range hood with the 6.5 x 9.5 mm screws provided.
NOTE: An optional 7" (17.8 cm) round damper is available as
an accessory. For information on ordering, see the
"Accessories"
section.
_A
!
D
A. 7" (17.8 cm) Round damper (see "Accessories"
section)
B. 6.5 x 9.5 mm screws
C. 7" (17.8 cm) round vent mounting plate
D. Round vent knockout
E. Rectangular
vent knockout
NOTE: The 7" (17.8 cm) round vent mounting plate can
be installed up to 1" (2.5 cm) on either side of the hood
center to accommodate
off center ductwork.
Power Supply
Cable Installation
1. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect
(or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the
instructions
in the "Make Electrical Connection"
section.
NOTE: Do not reconnect power until the installation is
complete.
8