Whirlpool UXT5230AYS1 Instruções de instalação e manual de utilização e cuidados - Página 11
Procurar online ou descarregar pdf Instruções de instalação e manual de utilização e cuidados para Campânula de ventilação Whirlpool UXT5230AYS1. Whirlpool UXT5230AYS1 32 páginas. 30" (76.2 cm) and 36" (91.4 cm) range hood
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
3. Use UL listed wire connectors
and connect black wires (B)
together.
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
2=
F
E
A. White wires
B. Black wires
C. UL fisted wire connector
D. Green (or bare) ground wire
E. Home power supply cable or
power cord accessory kit
F. UL listed or CSA approved
Y2"strain relief
G. Green ground screw
Use UL listed wire connectors
and connect white wires (A)
together.
4. Connect green (or bare) ground wire from power supply to
green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6. Reconnect power.
1. Replace the 2 bottom panels.
a.
Place the back of the panel into the rear channel and
push the panel toward the back of the range hood until
the tabs on the front of the panel clear the front mounting
flange.
b.
Push the front of the panel up into the front mounting
flange until the panel tabs align with the slots in the front
mounting flange. Release the panel so the tabs lock the
panel in place.
2. Replace grease filter. See the "Range Hood Care" section.
3. Check the operation of the range hood fan and light. See
"Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect
power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
11