ABB jokab safety Smile 11SA Tina Manual de instruções original - Página 8
Procurar online ou descarregar pdf Manual de instruções original para Unidade de controlo ABB jokab safety Smile 11SA Tina. ABB jokab safety Smile 11SA Tina 11 páginas. Emergency stop with safe as-i input slave
Também para ABB jokab safety Smile 11SA Tina: Manual de instruções original (12 páginas)
5
Operation
Smile 11EA AS-i
Emergency stop:
Push the emergency stop button. An actuating force of 22 ± 4 N is required and the actuator travel is approximately
4 mm to latch.
Unlatch emergency stop button:
Turn the button clockwise until the button is unlatched.
Smile 11SA AS-i
Safety stop:
Push the safety stop button. An actuating force of 22 ± 4 N is required and the actuator travel is approximately 4
mm to latch.
Unlatch safety stop button:
Turn the button clockwise until the button is unlatched.
LED indication
The LED indication is identical on both models (Smile 11EA AS-i and Smile 11SA AS-i).
LED in pushbutton:
The LED indication is programmed individually in the PLC-program according to the table below.
LED
Indication
ON
Red
OFF
ON
Green
OFF
AS-i LED and Fault LED in combination:
LED pair by the M12-connector.
AS-i (Green)
OFF
ON
ON
Flash
2TLC172094M0201, rev. B
2012-08-03
Description
Out bit 1 ON
Out bit 1 OFF or Out bit 1&2 ON.
Out bit 2 ON
Out bit 2 OFF or Out bit 1&2 ON.
Fault (Red)
Description
OFF
AS-i power missing
OFF
Normal operation
ON
No data exchange with master
ON
No data exchange because address = 0
8
www.abb.com/lowvoltage