HEATING WITH ELECTRICITY
Proceed as follows to activate heating with electricity. The more power (wattage) you select, the quicker
heating will take. A priority can be set when selecting both electricity and gas, see section 7:1 point 3.
The boiler uses no more power than is needed, even if it is set for 3kW.
+22°C
1 kW
5:4
HEATING WITH GAS
Proceed as follows to activate heating with gas. A priority can be set when selecting both electricity and
gas, see section 7:1 point 3.
+22°C
1 kW
5:5
*FULLY AUTOMATIC CLIMATE CONTROL (ACC)
If a Truma AC is connected up to the Alde, then the ACC button is visible and it is possible to control ACC from
the panel. This function makes it possible to have fully automated climate control for both heating, cooling and
hot water. The button is not visible if 230 V is connected from the AC. With an outside temperature sensor
fitted, ACC function is improved: operation of the AC is modified in line with the outdoor temperature.
no. 3010 299)
Figure 1
+22°C
1 kW
ACC
1. Set the desired temperature.
2. Press the blue ACC button, the
button turns green (see fig. 2) and
the ACC function is switched on,
but is not necessarily in operation.
If gas and/or electricity is switched
on, AC and the boiler work to de-
liver the temperature set, regard-
less of whether heat or cooling is
needed in the vehicle. To turn off
the ACC function, press the ACC
button and it becomes blue.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
6
manufacturer's instructions.
1. Use the + or - button to switch
on the electric heating and toggle between the various power
modes (Off, 1 kW, 2 kW or 3 kW) The set value will be displayed
on the screen. The activated mode is indicated by the + button
changing colour to green. If a *load monitor is installed and set,
the boiler will not use more electricity than it is capable of even if
3 kW is selected.
2. The settings are now complete and the boiler is working at the set
temperature.
3. To switch off electrical operation, use the - button to toggle to Off.
1. Start gas operation by pressing the LPG flame symbol. The LPG
symbol is activated and changes colour to green.
2. The settings are now complete and the boiler will work at the set
temperature.
3. To switch off gas operation, press the LPG flame symbol. It will
now change to blue.
Figure 2
+22°C
1 kW
ACC
The remote control for AC can be
used in this mode.
NB. Temperature sensors that are
used when fully automatic climate
control is in operation must be
positioned so that they are influ-
enced equally by the heat from
the Alde heating system and the
air from the AC. In certain cases it
can be an advantage to use Alde's
temperature sensor
(part no. 3010
638).
Figure 3
+22°C
1 kW
ACC
3. To turn AC lighting off and
on, press the button rapidly.
When the button is kept
pressed in, the light changes
from dark to light and then
back (light to dark) and so
on in 10 brightness levels.
When the button is relea-
sed it stays at the current
brightness. This button is
only visible when AC* is con-
nected.
(part