Material Safety Data Sheet
XEROX
Material Sa{ety Data Sheet
MSDS No:
A-0198
Date:'
1212194
Revision:
412987
Manufacturer: Xerox Corporation
Telephone # (s):
Safety lnformation; (800) 828-6571
Rochester, NY 14644
Health Emergency: (7'16) 422-2177
T ran spo ftation E m e rgency : (7 1 6\422- 1 23b
Section l- Product ldentification
Trade Names/Synonyms: 5201 15203/5305/5306, XC351r(C355r(C356
Black Dry Ink Cartridge
Part No.: 6R737
Chemical Name: None
WHMIS Status: This is not a WHMIS controlled Droduct.
Inqredients (% bv vut,)
lron powder (50-60%)
Styrene/acrylate copolymer (40-50%)
Carbon black (<6%)
C.l. Solvent BlackT (<2"/"\
Polypropylene (<3%)
Magnetite (<2%)
CAS No.
7439-89-6
25767-47-9
1 333-86-4
8005-02-5
9003-07-0
1 3 1 7 - 6 1 - 9
Primary Route of Entry:
lnhalation
Eyes:
Flush with water.
Skin;
Exposure:
Wash with soap and water.
Inhalation:
Remove from exposure.
Section ll - Emergency and First Aid
Symptoms of Overexposure:
Minimal respiratory tract initation may occur as wilh
exposure to large amounts of any non-toxic dust.
Medical Conditions Generally Aggravated by
None when used as described by product literature
Additional Information:
TLV: 10 mg/m'(total dust)
PEL: 15 mg/m" (total dust)
5 mg/m' (respirable dust)
S T E L : N , E
C e i l i n g : N . E .
XEL2: 2.5 mg/m3 (total dust)
0.4 mg/m3 (respirable dust)
Ingestion:
None.
Dilute stomach contents with several glasses of water.
Section lll - Toxicology and Health Information
This material has been evaluated by Xerox Corporation.
Oral LDso: >5 g/kg (rats) practically non{oxic.
Dermal LDso: >5 g/kg (rabbits) practically non{oxic.'
Inhalation LCso: >5 mg/l (rats, 4 hr exposure) practically
nontoxic. 1 >2O mgfl (calculated t hr exposure) 1
Eye lrritation: Nol an irritant.
Skin Sensitization: Not a sensitizer.
1
Skin lrritation: Notan irritant.
Human Patch: Non-irritating, non-sensitizing.
Mutagenicity: No mutagenicity detected in Ames, WP2, Yeast D7, and Mouse Lymphoma
Assays.
Carcinogens: None present
Aquatic LCso: N.D.
Material Safety Data Sheet
l Based
on testing of similar xerographic toner materials. 'XEL-Xerox Exposure Limit
N.A. - Not Applicable N.E. -None Established N.D. -Not Determined
602E03300
44