USER GUIDE | VersAlarm™ I/O

Troubleshooting

PROBLEM
Green LED on the enclosure does not
turn on during initial setup
While using a WaterSpotter™ sensor
or probe, the alarm conditions resume
without the presence of water
While using a float switch, the alarm
conditions are resuming with an empty
tank
While using a vertical switch, the alarm
conditions are resuming with an empty
tank
Sensor is activated, but the red LEDs on
the enclosure are solid and the buzzer is
not annunciating
The auxiliary contacts are not activating If the alarm is not activated, then the
14 | Alderon Industries™ - Leading Edge Control Products
PROBABLE CAUSE
Power not applied or power loss
Green LED turn off feature activated
The probes could be dirty
Check to see if the float switch is hung
up on something
If the float switch is old, the contacts
could be stuck shut
The float on the vertical switch could be
dirty with a lot of build up to restrict float
movement
If the vertical switch is old, the contacts
could be stuck shut
The silence pushbutton has been
pressed
auxiliary contacts should also be off
SOLUTION
Check to see if alarm is plugged in, have
qualified personnel check receptacle
with voltmeter and make sure circuit
breaker is not tripped
Check green power LED switch to make
sure it is in the on position (up), if off
(down), flip the switch up and back to
the on position
Disconnect all power sources from the
alarm and clean probes
Make sure the float switch is free and
the line is tethered at desired location in
a secure fashion
Replace the float switch
Pull up vertical switch, clean it off and
check for free movement of the float
Replace the vertical switch
Deactivate or disconnect the sensor and
then reactivate or reconnect the sensor
to ensure normal operation resumes
Test the alarm and the auxiliary contacts
should work while the alarm is activated