Alderon Industries WaterPro VA02A Manual de operação, manutenção e instalação - Página 2

Procurar online ou descarregar pdf Manual de operação, manutenção e instalação para Painel de controlo Alderon Industries WaterPro VA02A. Alderon Industries WaterPro VA02A 4 páginas. Alarm panel

WaterPro
Alarm Panel
Model - VA02A
Operation, Maintenance and Installation Manual
Installation of the WaterPro™ Alarm Panel
1. To install/replace the battery for the backup power feature, remove the access cover (Fig. 1) and install 9 VDC battery
(Duracell model MX 1604B2) (Fig. 2). After installing battery, press the test button (Fig. 3) to activate the alarm to make sure
the battery works properly. The alarm indicator lights should illuminate and the buzzer should annunciate. If using the auxila-
ry contacts, leave cover off until step 3 is completed. If you are not using them, replace the access cover (Fig 4).
(Fig. 1)
(Fig. 2)
(Fig. 3)
(Fig. 4)
2. Determine mounting location for the WaterPro™ Alarm Panel. Make sure power outlet is within 5 feet of the WaterPro™
Alarm (Fig. 5). Make sure the outlet in on a separate circuit breaker from any other device and not on a switched receptacle
to maintain power integrity. Mount the WaterPro™ Alarm using two #6 self tapping screws (not included) (Fig. 6). Use #8
plastic anchor (not included) if mounting to sheet rock (Fig. 7).
5 ft max
(Fig. 5)
(Fig. 6)
(Fig. 7)
Page 2 of 4
PO Box 827 Hawley, MN 56549 Phone: (218) 483-3034 Fax: (218) 483-3036 www.alderonind.com