eControls Comfort365 C365C32 Manual do instalador - Página 5
Procurar online ou descarregar pdf Manual do instalador para Termostato eControls Comfort365 C365C32. eControls Comfort365 C365C32 8 páginas. Wiring hub, model wh11 and wh32
Também para eControls Comfort365 C365C32: Manual do instalador (4 páginas)
ACCESSING INSTALLER OPTIONS
To access the Installer Options, TOUCH and HOLD the hidden Enter
key for 7 seconds until the first Option appears on the screen.
Upstairs
Airflow %
Auto
Downstairs
Day
Tu
AM
MENU
MODE
The hidden BACK key can be
used to return to previous options.
Press the touchscreen with your fingertip only, using a firm
!
touch. Do not use a sharp object such as a pen or pencil.
!
The NEXT key is used to display the next option.
The ENTER key is used to save options and return to normal
!
thermostat operation.
The hidden BACK key is used to return to previous options
!
and is located to the left of the NEXT key.
01 Selecting the Equipment Type
Factory Default: GE. Range: GE or HP
This option is used to select gas/electric or heat pump equipment.
Touch the UP/DOWN keys to
select gas/electric (GE) or heat
pump (HP).
Touch NEXT or ENTER.
02 Heat Pump Type
Factory Default: Co. Range: Co or dF
This option is used to select a conventional HP(Co) with electric
auxiliary heating or a dual fuel HP(dF) with fossil fuel auxiliary heating.
Touch the UP/DOWN keys to
select Co for conventional HP
or dF for dual fuel HP.
Touch NEXT or ENTER.
03 Dual fuel HP OBP
Factory Default: 40. Range: 35 to 55
This option is used to set the outdoor temperature at which the dual
fuel heat pump switches to fossil fuel heating.
Touch the UP/DOWN keys to
set the outdoor temperature
limit.
Touch NEXT or ENTER.
Cool
Set To
Schedule
Inside
COOL
SYSTEM
AUTO
FAN
TOUCH
and
HOLD
this key for 7 seconds
to access the Installer Options.
Option
NEXT
ENTER
(Only displayed if HP selected)
Option
NEXT
ENTER
(Only displayed if HP selected)
Option
Next
ENTER
04 Setting the Compressor Stages
Factory Default: 1 . Range: 0 or 1 for WH11 or 0 to 2 for WH32
This option is used to set the
number of compressor stages.
Touch the UP/DOWN keys to
set 0 or 1 stage.
Touch NEXT or ENTER.
05 Setting the Heating Stages
Factory Default: 1 Stage. Range: 0 or 1 for WH11 or 0, 1 or 2 for WH32
This option is used to set the
number of heating stages in a
GE system or auxiliary heating
stages in a HP.
Touch the UP/DOWN keys to set 0, 1
or 2 stages.
Touch NEXT or ENTER.
06 Setting the Fan Operation
Factory Default: Gas. Range: GA or EL
Touch the UP key to select "EL" for
electric operation where the
thermostat activates the indoor fan (G
terminal) during heating calls or
DOWN key to select GA for gas
operation where the equipment
plenum sensor activates the indoor
fan in heating calls.
Touch NEXT or ENTER.
07 Compressor Minimum Off Time
Factory Default: 2 Minutes. Range: 0 to 9 Minutes
Touch the UP/DOWN keys to change
the minimum off time (minutes) before
restarting the compressor.
Touch NEXT or ENTER.
08 Heating Minimum Off Time
Factory Default: 0 Minutes. Range: 0 to 9 Minutes
Touch the UP/DOWN keys to change
the minimum off time (minutes) before
restarting a gas furnace or electric
strip heater.
Touch NEXT or ENTER.
09 Minimum Run Time
Factory Default: 1 Minutes. Range: 0 to 9 Minutes
Touch the UP/DOWN keys to change
the minimum run time (minutes)
before turning a system off.
Touch NEXT or ENTER.
5
Option
NEXT
ENTER
Option
NEXT
ENTER
(Only displayed
if GE selected)
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER