Wiring FC2J to 2-Speed WHF
For 2 speed WHFs, the PWM and COM wires should be
cut off at the PCB. Use wirenuts to connect the FC2J
wires to the WHF wires and the incoming 120VAC power
wires.
FC2J Wire
Connects
High Speed (Purple)
WHF High Speed (Black)
Low Speed (Red)
WHF Low Speed (Red)
Neutral (White)
WHF Neutral (White) and
120VAC Neutral (White)
Ground (Green)
WHF Ground (Green) and
Power Ground (Green)
120VAC (Black)
Power 120VAC (Black)
Wiring FC2J to Variable Speed ECM WHF
For variable speed WHF using PWM speed control, the
High Speed and Low Speed wires should be cut off at
the PCB.
FC2J Wire
Connects
PWM Com (Blue)
WHF PWM Com (Black)
PWM (Red)
WHF PWM (Red)
Neutral (White)
WHF Neutral (White) and
120VAC Neutral (White)
Ground (Green)
WHF Ground (Green) and
Power Ground (Green)
120VAC (Black)
Power 120VAC (Black)
and WHF 120VAC(Black)
INSTALLER SECTION
The FC2J and RM2 are connected using the 7-foot RJ11
cable provided with the FC2J. The RM2 can be attached
to a surface (not metal) using the two mounting tabs or
left suspended by the RJ11 cable.
Electrical box on WHF
Plug one end of the cable into the FC2J and the other
end into the RM2 Radio Module. The RT2 wireless
control is now ready to communicate with the RM2 and
control the FC2J.
Power
Cord
The optional TS3 Outdoor Temperature Sensor should
be installed under the eaves of the home and out of
direct sun light. The outdoor temperature sensor is used
to inhibit WHF operation when the outdoor temperature
is too warm to provide cooling.
Electrical box on WHF
Use 2-conductor AWG 20 to 24 wire to connect the
temperature sensor to the ODT terminals on the RM2
Radio Module. The sensor is not polarized.
Power
Cord
6
Connecting FC2J to RM2 Radio Module
FC2J Relay Board
RM2 Radio Module
RJ11 7-foot cable
supplied with FC2J
Installing the Outdoor Temp Sensor
Wire Nuts
Sensor and
Cover
Screw attaches Cover to Mounting Plate.
Wall
Gasket
Mounting Plate
Mounting Screws