Dante Messages (XMV4280-D/XMV4140-D only)

Warnings and certain other types of information are displayed via the XMV4280-D/XMV4140-D front panel indicators.
Messages are also displayed in the Dante Controller Error Status field.
Each indicator lights or flashes as described below:
Unlit
The indicator is off.
Lit
The indicator remains lit steadily.
Flash
The indicator continues to flash.
Flash x 2
The indicator flashes twice cyclically.
Information Messages
The status is shown by the lit/flashing state of the indicator.
If the orange [SYNC] indicator is unlit, the unit is operating normally.
If the green [SYNC] indicator is unlit, the unit's clock is unconfirmed.
SYNC Indicators
(green) Unlit
(orange) Lit
(green) Flash
(orange) Unlit
(green) Lit
(orange) Unlit
Warning Messages
The indicator will remain lit or continue flashing cyclically until the problem is solved.
If the green [SYNC] indicator is unlit, the unit's clock is unconfirmed.
SYNC Indicators
(green) Unlit
(orange) Flash
(green) Unlit
(orange) Flash x2
If the green indicator is flashing, the unit is the clock master.
If the green indicator is lit, the unit is the clock slave and the clock is synchronized.
SYNC Indicators
(green) Lit or flash
(orange) Lit
(green) Lit or flash
(orange) Flash
(green) Lit or flash
(orange) Flash x 2
Description
Synchronization is occurring.
The unit is functioning correctly as the word clock
master.
The unit is functioning correctly as the word clock
slave.
Description
The word clock is not set correctly.
Dante Network circuit is broken.
Description
A non-GbE-compatible device is connected.
The Dante [SECONDARY] connector has taken
over communications during redundant network
operation.
An abnormality has occurred on the circuit con-
nected to the Dante [SECONDARY] connector dur-
ing redundant network operation.
Please wait until the unit synchronizes
completely. It may take approximately 60
seconds for synchronization to be com-
pleted.
The unit is operating as the word clock
master.
The unit is operating as the clock slave
and the clock is synchronized.
Set the clock master and sampling fre-
quency correctly on the MTX Editor or in
Dante Controller.
Make sure that the Ethernet cables are
not removed or short-circuited.
When transferring audio via Dante, use
device that supports GbE.
Check the circuit connected to the Dante
[PRIMARY] connector.
Check the circuit connected to the Dante
[SECONDARY] connector.
XMV4280/XMV4140/XMV4280-D/XMV4140-D Owner's Manual
Appendix
Explanation
Possible Solution
Possible Solution
29