3.CONTROLLER INTRODUCTION
Factory default setting on controller :
all parameters can only be adjusted under stand-by status.
Fig.
Description and content:
Stand-by status: Outlet water temperature:
1
Stand-by status: Target/setting water tempertaure
Running status: Outlet water temperature
2
Running status: Target /setting water temperature
3
available functions:Main
main menu: Mode select/Unit status
4
Mode select :
5
Aux heating
Fan mode
6
Unit status
1.0 Operation
2.0 Aux heaitng
2.1 Start temperature
2.2 Start delay
3.0 Defrost
3.1 Defrost cycle
3.2 Defrost in temperature
7
Parameter
3.3 Defrost out temperature
3.4 Max time
4.0 Save
4.1 Power save
5.0 Disinfection
5.1 Target temperature
5.2 Maintain time
6.0 Swell valve
6.1 Mode
6.2 Over heat
6.3 Adjust step
Maintenance
see "Ordinary malfunctions and Solutions"
8
Date
Clock
Timer 1 on
Timer
9
Timer 1 off
Timer 2 on
Timer 2 off
Alarm (P01~E08)see"Ordinary malfunction and
10
Solutions" table
1.1 Out water
1.2 ▲T1(heating)
Setting range /option
/
10~60°C
/
/
as select option
as select option
as select option
on/off
on/off
Tank top temperature.
Tank bottom temperature
Pipe temperature
Evaporator temperature
Ambient temperature
Swell valve
10~60°C
2~15°C
30~90°C
0~90 *5min
30~90 minute
-30~ 0°C
2~30°C
1~12 Minute
0(NO)/1(YES)
30~70°C
0~90Minute
Auto/Manual
-20~20°C
100~500 N
/
/
√ (YES)/ ×(NO)
√ (YES)/ ×(NO)
√ (YES)/ ×(NO)
√ (YES)/ ×(NO)
/
13
Default
Remark
value
Actual tested value,not adjustable
/
Adjustable
55°C
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
/
/
/
/
/
/
Adjustable
off
Adjustable
off
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
Actual tested value,not adjustable
/
Adjustable
55°C
Adjustable
5°C
Adjustable
55°C
Adjustable
40 *5min
Adjustable
45minute
Adjustable
-7°C
Adjustable
13°C
Adjustable
8 Minute
Adjustable
1(YES)
Adjustable
65°C
Adjustable
30Minute
Adjustable
Auto
Adjustable
5°C
Adjustable
350 N
Actual running record, not adjustable
Adjustable
/
Adjustable
/
×(NO)
Adjustable
×(NO)
Adjustable
×(NO)
Adjustable
×(NO)
Adjustable
/
Actual running record, not adjustable