4. MAIN FEATURES
• Brushless motor 380-440Vac, 3ph, 50/60Hz, IP55
• Max temperature +50°C
• Speed controllable
• Suitable for S1 continuous service
• Embedded electronic system
• Extruded aluminium blades
5. DATA @400Vac, 50Hz
No
Max speed
Model
blades
rotation
WHS400
5
WHS500
5
WHS600
5
(1) max. absorbed power / max. airflow
(2) min. average air speed 0.8m/s with testing layout in conformity with AMCA 230
6. DIMENSIONS AND CLEARANCES
Model
ØA
Modello
Model
mm
WHS400
4000
WHS400
WHS500
WHS500
5000
WHS600
WHS600
6000
7. COMPONENTS
Modello
Model
• The fan is delivered split into two kits, each one in its own box.
• MOTOR KIT includes:
WHS400
- main body (Fig.I - 1).
WHS500
- standard 800mm length downrod (Fig.I - 2).
WHS600
- 2x ceiling fixing brackets (Fig.I - 3 and Fig. VI).
- 2x fixings sets:
- 4x M12 bolts (Fig.I - 4), 4x locknuts (Fig.I - 5), 4x flat washer (Fig.I - 6) and 4x spring washers (Fig.I - 7), for fan fixing to
the ceiling.
- 10x M8 flange bolts (Fig.VIII - 8), 10x locknuts (Fig.VIII - 9) and 10x spring washers (Fig.VIII - 10) and 10x plastic caps (Fig.
VIII – 14), to fix the blades to the main body.
- plastic components set: hub cover (Fig.IX - 11), 5x M4 bolts (Fig.IX - 12).
- security wires set: 1x Ø5mm security wire with one ring (Fig.I and II - 16), 2x Ø5mm wire with two rings (Fig.II - 17), 2x clamp
(Fig.VII - 18), 2x 7mm snap-hook (Fig.II and V - 19), 1x shackle (Fig.II - 20) for the security wire, 4x Ø3mm stabilizing wires
with turnbuckle (Fig.X - 21), 5x 5mm snap-hooks (Fig.X - 22) and 8x clamp (Fig.XIII - 23) for the stabilizing wires.
• BLADES KIT incudes five blades (Fig.VIII - 13).
• The electrical wire type (Fig.III – 15 – not supplied) must comply with the local regulations of the electric system and must
have the following features:
- 4 core supply power cable (section ≥ 1mm
- 6 core control cable (section ≥ 0.5mm
Note: the voltage drop cannot be higher than 4%.
Max
Max
absorbed
Thrust
power
r/min
kW
N
120
0.8
272
105
1.1
366
84
1.4
302
C
B
β
min safety distance
max ceiling slop
ØA
Inclinazione max
from side obstacle
del soffitto
Max ceiling slop
mm
>
°
mm
°
450
4000
5000
20°
20
550
6000
650
β
ØA
Inclinazione max
del soffitto
Max ceiling slop
mm
°
4000
5000
20°
6000
)
2
)
2
• Gearless for silent operation
• Maintenance-free
• Key Safety features
• Simplified electrical wiring connection
• Strong and robust design and manufacturing
Max airflow
AMCA 230-15
SPI
(1)
cfm
m
/h
3
W/(m
/s)
3
113086
192133
15.0
152319
258791
16.0
178738
303677
16.6
ØA
ØA
ØA
D
C
D
fan height with
standard downrod
Distanza minima da
Altezza con tubolare
Lunghezza tubolare
standard downrod
qualsiasi ostacolo
standard
Min safety distance
Fan height with
Standard downrod
from side obstacle
standard downrod
mm
mm
mm
450
550
1300
1300
650
C
D
Distanza minima da
Altezza con tubolare
Lunghezza tubolare
qualsiasi ostacolo
standard
Min safety distance
Fan height with
Standard downrod
from side obstacle
standard downrod
mm
mm
450
550
1300
650
12
Max airflow
AMCA 230-99
SPI
(1)
cfm
m
/h
3
W/(m
/s)
3
159927
271717
10.6
215412
365986
11.3
252774
429464
11.7
E
H
E
H
min fan
Altezza minima di
Peso
length
installation height
standard
installazione
Min fan installation
lenght
height
mm
mm
mm
mm
105
800
2700
127
800
2700
143
E
H
Altezza minima di
Peso
standard
installazione
Min fan installation
lenght
height
mm
mm
105
800
2700
127
143
Affected
diameter
2)
m
38
46
64
Weight
kg
kg
105
127
143
kg