Clarke CFP9ND Manual de operação e manutenção - Página 7

Procurar online ou descarregar pdf Manual de operação e manutenção para Compressor de ar Clarke CFP9ND. Clarke CFP9ND 10 páginas. Air compressor

Clarke CFP9ND Manual de operação e manutenção
Compressor unit runs
Large amount of condensation in
on and off load more
air receiver.
frequently than usual.
Leaks in system
Compressor unit runs
Leaks in system.
'on load' when no air is
being used.
Compressor's oil
Too much oil in compressor.
consumption rising.
Leaks around crank case.
Working temperature of
compressor too high because of
insufficient cooling.
Cylinder worn.
Intake air filter blocked.
Oil in the air delivered.
Sump over full.
Cylinder worn.
Intake air filter blocked.
Oil level rises although
Condensation in oil pump.
no oil has been put in.
Condensation at outlet
Piping installation incorrect.
points.
Compressor taking in air which is
too warm.
Drain off condensation Regularly
(Every day before use).
Locate leaks (by means of soapy
water) and repair.
Locate leaks (by means of
soapy water) and repair.
Check oil level 2 or 3 minutes after
stopping.
Change seal and inspect
packing surfaces. Repair or
replace defective parts.
Increase ventilation to air
compressor.
Replace worn parts or send
compressor pump for an
overhaul.
Change air filter.
Reduce oil to correct level.
Replace worn parts or send
compressor pump for an
overhaul.
Change air filter.
Compressor over dimensioned.
Consult your local dealer.
Obtain better fresh-air supply to
compressor.
- 14 -
PREPARATION FOR USE
A.Environmental
Ensure the compressor is sited on a firm level surface.
Ensure the environment is dry and dust free.
Ensure there is adequate ventilation for:
a) Air intake to compressor pump
b) Cooling for compressor pump
c) Engine exhaust gases.
B. Engine
Check oil and fuel levels and a visual check of components. Refer to engine service manual.
C. Pump
Check oil level on the Dipstick - to level marked.
D. Fueling
Fill with unleaded petrol, according to the instructions within the engine manual.
Ensure the fuel tap is set to the required position.
Ensure The fuel hose and connectors are intact, in perfectly servicable
condition and there is no leakage.
Note : Always use a funnel to fill the fuel tank so as to avoid accidental spillage of
fuel. If fuel is spilled it must be removed from the unit and surrounding area, before
attempting to start the engine.
E. Receiver
Drain off any condensate, by opening the drain cock (see Fig. 1). Remember
to close the cock when completed.
NOTE: This should be carried out DAILY when the compressor is in constant use.
F. Air Hose & Air Tool
Attach the air hose to the outlet using an appropriate connector.
NOTE: Quick fit nuts are provided with model PP9ND
Attach the air tool/spray gun to the air hose...If using snap couplings, use
a whip end, available from your Clarke dealer.
- 7 -