Safety Precautions
NEVER STOP THE COMPRESSOR BY REMOVING THE PLUG OR SWITCHING OFF AT THE
MAINS SUPPLY: Always use the On/Off switch on the compressor.
NEVER OPERATE WITHOUT ALL GUARDS IN PLACE: Never operate without all guards
or safety features in place and in proper working order.
NEVER OPERATE IN THE PRESENCE OF FLAMMABLE LIQUIDS OR GASES: The air
compressor produces sparks during operation.
CHECK FOR DAMAGED PARTS AND AIR LEAKS: If any part of the compressor is
damaged, it should be carefully checked to determine that it will operate correctly
and perform its intended function. Check for the alignment of parts, damage to
parts, air leaks and any other conditions that may affect its operation. A guard or
any other part that is damaged or defective should be properly repaired or
replaced by an authorised service centre. Defective pressure switches must be
replaced prior to further use of the compressor.
ONLY USE WITHIN THE RECOMMENDED OPERATING TEMPERATURE RANGE: This
compressor should only be used in an ambient temperature of between 0
25
O
C.
CLEANING AND CONDITION OF THE COMPRESSOR: Keep the external surfaces of
the tank clean. Avoid impact damage and do not allow the tank to come into
contact with abrasive or corrosive materials.
MOVING THE COMPRESSOR: Always transport the compressor by lifting or pulling it
with the appropriate grips or handles.
USING THE COMPRESSOR FOR PAINTING:
Do not work in enclosed areas or near naked flames.
Make sure that the area in which you are working has good ventilation.
Protect your nose and mouth with a suitable face mask.
Always check the safety data sheets for substances being sprayed & ensure
manufacturers instructions are followed.
MOTOR HOUSING: Do not insert your fingers or other objects inside the motor housing
to avoid physical damage or damage to the compressor.
O
C and
8

Operating Instructions

Draining the reservoir
CAUTION! It is important to drain the reservoir before storage.
1
Pressing the red on/off button down to switch the air compressor off and
remove the plug from the mains supply.
• Place a suitable container beneath the compressor to catch any
condensation.
2
Carefully undo the drain valve until you hear a hissing noise, this is the
reservoir depressurising. See figure 9.
• When the reservoir pressure gauge indicates zero and the hissing has
stopped, tighten the drain valve again.
Drain valve
Figure 9
17