Carefully unscrew the non return
valve assembly from the vertical
hex. riser, then disassemble. Clean
or renew the rubber disk before
reassembling.
With the valve restored, start the machine with the flexible pipe disconnected to
check for leaks. If leaks persist, renew the valve assembly, otherwise reconnect
the flexible pipe.
FAULT FINDING
PROBLEM
The compressor will
Bad connections.
not start, or stops
and will not start
Blown fuse
again.
Overload cutout switch
has tripped.
Compressor does
Air receiver charged
not start.
The compressor
does not reach the
set pressure and
overheats easily.
Air leaking from the
Faulty non-return valve.
pressure switch
valve when the
compressor is not
running.
Air pressure from
the regulator will
not adjust.
Compressor
Inlet Air Filter Blocked
operating, but no
Pressure Regulator closed
air from outlet
Drain valve open
Bleed Pipe (from Pressure
Switch to non-return valve)
broken or disconnected
PROBABLE CAUSE
I
nlet Air Filter is blocked
NOTE: It is also possible
that you are using more
air than the compressor is
capable of delivering.
The diaphragm within the
regulator body is broken.
10
REMEDY
Check the electrical connections.
Clean and tighten as necessary.
Replace fuse
Wait 25-20 mins before attempting
to restart
Open drain valve to expel air.
Compressor should start again when
pressure reduces to approx. 95 psi.
Renew Oil Filler/Air Filter plug
First drain the receiver completely
of air. Renew the non-return valve.
Replace Regulator
Renew Oil Filler/Air Filter Plug
Turn Regulator clockwise to set
required pressure
Close Drain Valve
Reconnect or replace Bleed Pipe