Clarke 7160042 Manual de Instruções de Operação e Manutenção - Página 6
Procurar online ou descarregar pdf Manual de Instruções de Operação e Manutenção para Bomba de água Clarke 7160042. Clarke 7160042 13 páginas. 12&24v diesel fuel transfer pumps
CONNECTION & OPERATION
WARNING: DO NOT USE WITH PETROL OR ANY OTHER HIGHLY FLAMMABLE
LIQUID TO DUE TO THE POSSIBILITY OF SPARKING TAKING PLACE AND
CAUSING FIRE.
1. Fit the carrying handle to the
pump with the hex screw & washer
provided.
2. If required, the pump can be
installed in any horizontal
mounting position and mounted to
a flat surface using screws of
adequate size (not supplied)
through the mounting holes in the
base.
• The pump should not be installed at more than 6m above the fuel
supply.
3. Before connecting the pump, remove the travel plugs from the inlet/outlet
ports.
4. If not already fitted, screw the inlet filter to the plastic suction hose.
5. Screw in either:
• A) the inlet and outlet hoses
supplied or
• B) the inlet adaptors for use with
19 mm hoses
NOTE: The transparent suction hose is
connected to the side of the
pump marked "IN" and the
delivery hose to the side
marked "OUT" on the pump
casting.
• The hose and connections need to be completely air tight,
otherwise air will be drawn in and reduce the flow. If required use
PTFE tape.
6. Before connecting the delivery hose FOR THE FIRST TIME, partially fill the
pump body with fuel to facilitate priming. Ensure the hoses and tank are
free from contamination.
7. Insert the transparent suction hose & filter into the diesel fuel container.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
6