Installation
Additional items that should be incorporated into the
air piping systems are listed in Table 4.
Part Number
5604-2
Moisture Separator
7604-B
Regulator and Gauge
Table 4 Air Line Components
Alemite Corporation
Description
Packing Adjustment
IMPORTANT: Break-in and wear of upper
packings require the user to readjust the
Packing Screw Assembly:
• after approximately 6 hours of initial operation *
• anytime the upper packings leak
1. Make sure the air pressure is zero.
2. Operate the control valve into a container.
• This releases any pressure within the system.
3. Insert the Adjustment Rod into one of the holes in the
Packing Screw Assembly.
4. Tighten Packing Screw Assembly (9) clockwise 1/4-
turn.
5. Set the air pressure to 30 psi (2.1 Bars).
6. Hold the control valve open while aiming into a
suitable collection container.
7. Loosen the Packing Screw Assembly until the pump
assembly begins to cycle.
* Applies to new and overhauled pumps.