Alemite 7785-MA Manual de serviço - Página 12

Procurar online ou descarregar pdf Manual de serviço para Bomba de água Alemite 7785-MA. Alemite 7785-MA 14 páginas. High-pressure grease pump

Alemite 7785-MA Manual de serviço
SER 7785-A5
Priming
With air pressure at zero:
8. Place the pump in the product to be dispensed.
9. Slowly supply air pressure to the pump's motor.
10. Allow the pump to cycle slowly until the system and
product is free of air.
If the pump assembly does not prime, refer to the
Troubleshooting Chart for details.
11. Check the motor for air leakage.
If the motor leaks, refer to the Air Motor Service
Guide for details.

Stall Test

WARNING
Should leakage occur anywhere within the
system, disconnect air to the motor. Personal
injury can occur.
With air pressure at zero:
12. Attach a control valve to the outlet hose of the pump.
13. Set the air pressure to 100 psi (6.9 Bar).
14. Operate the control valve into a container.
15. Allow the pump to cycle until the system and product
is once again free of air.
16. Shut off the control valve.
• The pump should not cycle.
If the pump cycles slowly (once or twice a minute) or
continuously, refer to the Troubleshooting Chart for
details.
Revision (11-08)
1-800-548-1191-http://[email protected]
Installation
NOTE: The following procedures consider
the pump assembly to be installed onto a
container with a cover.
1. Install the bolts that attach the cover to the pump
assembly.
• Tighten the bolts securely.
2. Place the follower into the container.
3. Press downward and maneuver the follower until
grease appears around its edges and center hole.
• Make sure all air is removed.
4. Install the pump assembly through the follower and
onto the container.
5. Secure the cover and pump assembly to the container.
Additional items that should be incorporated into the
air piping systems are listed in Table 5.
Part Number
338862
Moisture Separator/Regulator & Gauge Combination
5608-2
Moisture Separator
7608-B
Regulator and Gauge
5908-2
Lubricator *
Table 5 Air Line Components
* Although the air motor is lubricated at the factory,
the life of the motor can be extended with the use of a
lubricator.

Alternate Installations

Pump model 7785-A5 is often mounted:
• from either a single- or dual-post hoist
• in bulk grease distribution systems
When either of these type arrangements are employed,
alternate accessory items must be purchased. See Table 6.
Application
Followers
327242
Single-Post Hoist
Dual-Post Hoist
327690
Bulk Grease
* 1-1/2 " NPTF (m)
Table 6 Accessory Items for Alternate Installations
12
High-Pressure Grease Pump
Description
Adapter Kit
Primer Body
327247
333693*
Alemite, LLC