Clarke 7236046 Manual de Instruções de Operação e Manutenção - Página 6

Procurar online ou descarregar pdf Manual de Instruções de Operação e Manutenção para Bomba de água Clarke 7236046. Clarke 7236046 13 páginas. 750w submersible pump with built-in float switch

Clarke 7236046 Manual de Instruções de Operação e Manutenção

OPERATING MODES

Set the mode switch to either
Automatic (Down) or Manual (Up)

AUTOMATIC OPERATION

The internal float switch will switch the
pump on when the water level
reaches approximately 165 mm and
switch off when the water level drops
to approximately 90 mm.

MANUAL OPERATION

The pump will run continuously.
NOTE: Keep watch and do not allow the pump to run dry

USING THE PUMP

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE
PUMP IF IT IS DAMAGED IN ANY WAY.
WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP
BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.
1. Connect the mains plug to the mains supply.
• Always use a high sensitivity residual current device (RCD) which has a
tripping current of less then 30 mA.
2. Switch the mains power supply on.
• The pump will begin to drain water.
• In Automatic mode, the internal float switch will turn off the pump when
the water level drops to approximately 90 mm.
3. When pumping is finished, disconnect the pump from the mains power
supply.
IMPORTANT: Do not allow the pump to run dry.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
6