Alemite 8430 Manual de serviço - Página 8
Procurar online ou descarregar pdf Manual de serviço para Bomba de água Alemite 8430. Alemite 8430 8 páginas. 1/3 hp def pump
SER 8430
Condition
Pump does not prime
The pump does not run
The pump runs but does not
deliver
Revision (7-12)
Probable Cause
1.See point nr. 4 — Installation information
1. Not plugged in
2. Thermal overload or Amperometric protection
tripped due to:
a) Overheating (the pump ran with hot water
or ran dry)
b) Shaft blocked
c) Impeller blocked
1. Air in the pump housing
2. Air bubbles in the suction line
3. Pump not primed
Changes Since Last Printing
Initial release
1. Clean or replace "reclassifi er fi ttings"
2. Remove "sags" in the inlet line
1. Check the electric power plug.
2. Remedy to :
a) Wait until thermal protector switches
back on after adequate cooling time al-
lowed.
b) Unplug the pump and with a screwdriver
twist the rear shaft side.
c) Unplug the pump, disassemble the pump
and clean it and remove the causes of the
overload / overheating switch off.
1. Unplug the pump. Take out discharge
line; shake the pump and suction pipe. Fill
up pump housing with DEF ; fi t discharge
line and switch on the Pump
2. Verify that suction line and fi ttings are
fi xed tight and that foot valve is correctly
mounted on suction line.
3. Read priming instructions
8
DEF Pump
Remedy
Alemite LLC