STORAGE
When the pump is not being used for extended periods, clean and dry it
thoroughly and store it indoors. If the pump is left in water, it should be run
occasionally to prevent it from seizing up in areas with a hard water supply.
FAULTFINDING
PROBLEM
PUMP WILL
NOT START
PUMP WILL
START BUT NOT
PUMP
PUMP WILL
NOT STOP
PUMP STOPS
RUNNING
WATER
DELIVERY IS
POOR
If this does not solve your problem, please contact the Clarke service
department.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
SOLUTION
1. Make sure that the power is switched on.
2. Check fuse (consult an electrician if in doubt).
3. If an extension lead is fitted, check connections (consult
an electrician if in doubt).
4. Float switch may be jammed against side wall, or
prevented from moving.
5. If the pump still fails to start, consult your CLARKE dealer
for advice.
1. Check that the inlet is not blocked.
2. Check that the outlet is not clogged or obstructed.
3. Air bubble in the pump, produced during immersion.
Immerse the pump again, at an angle, and shake it whilst
lowering to remove any air trapped in the system.
4. Impeller may be damaged - Consult your CLARKE dealer.
1. Float switch may be prevented from moving to the fully
down position.
2. Float switch may be faulty. Consult your CLARKE dealer
for advice.
1. Pump has run dry or float switch has cut in.
1. Blockage in hose.
2. Suction opening blocked.
3. Hosepipe kinked.
4. Hose diameter too small
7