Acorn TERRAZZO-WARE Series Procedimentos recomendados de limpeza e manutenção - Página 3

Procurar online ou descarregar pdf Procedimentos recomendados de limpeza e manutenção para Produto de canalização Acorn TERRAZZO-WARE Series. Acorn TERRAZZO-WARE Series 3 páginas. Shower bases

I N S T A L L A T I O N
ACORN ENGINEERING
COMPANY
4
RECOMMENDED PROCEDURE.
INSTALLATION INSTRUCTIONS:
1. Cut drain pipe to extend 1-3/8" into
drain body. Drain pipe should be even
with top of gasket when installation is
completed. Position Shower Base over
2" waste pipe making sure that pipe is
centered in drain body.
2. Lubricate gasket with soap solution and
stretch over 2" pipe with letters facing up.
3. Push gasket as far as possible into joint.
4. Using a hammer and caulking tool or
1/4" X 3/4" X 6" piece of wood instead
of a caulking tool, work around the
gasket with a series of blows and
gradually drive gasket into drain body
until it bottoms. Drain pipe should be
even with the top of gasket.
5. Test connection before covering or
concealing. To test: plug 2" drain and fill
receptor with water. Check for leaks.
Verify proper drainage. This must be
done before finishing walls.
WARNING!
2 5
MODELS WITH TILING FLANGE OPTIONS:
A. Do not let rough wall material overlap
flange.
B. Do not attach flange to building wall.
C. Let finished wall (tile, etc.) overlap and
rest on shoulder.
TERRAZZO-WARE
800-488-8999 or 626-336-4561
FAX 626-961-2200
P.O. BOX 3527 • CITY OF INDUSTRY, CA 91744-0527 (U.S.A.)
I N S T R U C T I O N S
Shower Bases
#1
2" WASTE PIPE
(BY OTHERS)
#2 & #3
ALTERNATE PROCEDURE
A. TAMP OAKUM TO 5/8" DEPTH
B. POUR MOLTEN LEAD.
C. TAMP LEAD CAREFULLY.
NOTE: 2" WASTE
PIPE AND "P" TRAP
BY OTHERS.
DO NOT ATTACH
LATH,
FLANGE TO WALL
PLASTER
BOARD, ETC.
A
Shower Bases
1-3/8"
FINISHED
FLOOR
OPTIONAL -KDG or
GASKET BY OTHERS
#4
A
B
TILE, ETC.
B
C
3030-737-000 Rev. 03/04/13
BASE
C
CAULKING